Login       My Wishlist
  My Cart
$0.00 / 0 items
 
In The National Interest
Politics and Policy in the Interest of the Nation
 
International Access
Global Shipping Options Available
Home About Us News Our Blog Our Catalog My Cart My Account Track Shippment Contact Us
  Our Catalog   Filtration

National Scientific Regenerated Cellulose Target Syringe Filter, Prefilter, 0.20µm Pore Size, 30mm Outside Diameter (Pack of 100)


Extreame Savings Item! Save 47% on the National Scientific Regenerated Cellulose Target Syringe Filter, Prefilter, 0.20µm Pore Size, 30mm Outside Diameter (Pack of 100) by National Scientific at In The National Interest. MPN: F2500-8. Hurry! Limited time offer. Offer valid only while supplies last. The polypropylene housings with all Target syringe filters are solvent resistant and exhibit low extractables. Ideal for filtering chromatography


Product Description

The polypropylene housings with all Target syringe filters are solvent resistant and exhibit low extractables. Ideal for filtering chromatography solvents and samples when combined with low extractable Nylon, Regenerated Cellulose or PTFE membranes. Meets the requirements of 21 CFR 177.1520. All types are supplied in packs of 100. Cellulose Acetate (CA) is a very low protein binding membrane ideal for aqueous based samples. An excellent choice for maximum protein recovery in filtrate. Laboratory studies show that CA membranes bind less protein than PVDF or Polysulfone membranes. When used with a glass prefilter, CA is ideal for tissue culture media filtration and sensitive biological samples. The prefilter increases yield. Cellulose Acetate is certified for Ion Chromatography. Regenerated Cellulose (RC) is a hydrophilic, solvent resistant, low protein binding membrane. It is the membrane of choice for low non-specific binding (biological analysis, protein, peptides). Suitable for removing particulates from HPLC samples prior to injection. Compatible with all HPLC solvents and aqueous samples in the 3 to 12 pH range. Used for particle removal and degassing of solvents. Extractables with water are less than 1%. Glass MicroFiber (GMF) membranes are commonly used as prefilters to remove large particulates and to extend the load capacity of the membrane. Membrane of choice for dissolution testing. GMF is certified for Ion Chromatography. Nylon (NY) membranes are naturally hydrophilic, solvent resistant, do not require pre-wetting and have low extractables. Can withstand solution up to 50°C. Can be used with organic or aqueous solutions. Flow rate is excellent. Not recommended for strong acids or bases. Commonly used for general laboratory filtration. Nylon binds protein and is not recommended when high protein recovery is needed. Available with glass prefilter. Polypropylene (PP) is a hydrophilic material that exhibits a wide range of chemical compatibility to organic solvents. A good choice for HPLC sample filtration when performing chromatography analysis. Highly solvent resistant. Low, non-specific absorbing membranes for maximum protein recovery. Well-suited for biological sample filtration. Also available with 1.0 µm built-in glass prefilter. Polypropylene is certified for Ion Chromatography. Polytetrafluoroethylene ( PTFE) is a hydrophobic membrane chemically resistant to all solvents, acids and bases. Membrane has high mechanical strength and can withstand high temperature liquids. Does not impart any extractables to the filtrate. PTFE blocks water vapor, making it ideal for transducer protectors. Also excellent for filtering and degassing organic and highly basic mobile phase solutions for liquid chromatography. Available with glass prefilter. Polyethersulsulfone (PES) is a naturally hydrophilic membrane that gives higher flow rates, lower extractables and low binding of protein and nucleic acids and can be used with high temperature liquids. PES is mechanically strong and resistant to a broad range of aqueous solvents. PES is the filter of choice for for tissue culture work. PES is certified for Ion Chromatography. Polyvinylidene Difluoride (PVDF) is a hydrophilic, solvent resistant membrane that exhibits low levels of UV adsorbing extractables. Low non-specific adsorbing membrane for maximum protein recovery in critical analysis. Also well suited for biological sample filtration.

Features & Highlights

  • 7 membrane types
  • Female Luer-Lock inlet, male Luer-slip outlet
  • Solvent resistant polypropylene housings
  • PES, GMF, Polypropylene and Cellulose Acetate membranes are certified for Ion Chromatography

Additional Information

Manufacturer:Thermo Scientific
Brand:National Scientific
Model:F2500-8
Part Number:F2500-8
Publisher:Thermo Scientific
Studio:Thermo Scientific
MPN:F2500-8
Package Weight:0.7 pounds
Package Size:6.7 x 1.9 x 1.9 inches

National Scientific Regenerated Cellulose Target Syringe Filter, Prefilter, 0.20µm Pore Size, 30mm Outside Diameter (Pack of 100) by National Scientific

Buy Now:
National Scientific Regenerated Cellulose Target Syringe Filter, Prefilter, 0.20µm Pore Size, 30mm Outside Diameter (Pack of 100)

Brand: National Scientific
4.3 out of 5 stars with 46 reviews
Condition: New
Lead Time: 1 - 2 Business Days
Availability: In Stock
$384.46
$205.65
You Save: 47%


Quantity:  

 


View More In Filtration.

 


Have questions about this item, or would like to inquire about a custom or bulk order?


If you have any questions about this product by National Scientific, contact us by completing and submitting the form below. If you are looking for a specif part number, please include it with your message.

First Name:
Last Last:
Email Address:
Your Message:

Related Best Sellers


mpn: F2500-9,
Solvent-resistant, low-extractable polypropylene housing. Syringe filters can be sterilized by autoclave at 125° for 15 minutes.Membrane: Hydrophilic Polypropylene. Low nonspecific protein binding. Max. operating temperature: 110°C. Max. operating ...

mpn: F2502-1,
The polypropylene housings with all Target syringe filters are solvent resistant and exhibit low extractables. Ideal for filtering chromatography solvents and samples when combined with low extractable Nylon, Regenerated Cellulose or PTFE membranes. ...

mpn: F2504-10,
For particulate removal prior to HPLC analysis. Recommended Sample Volume < 2mLMembrane: HPLC Certified Cellulose Acetate. Housing: medical grade, virgin polypropylene. Connections: enhanced female Luer-Lok inlet, male Luer slip outlet. Max. operatin...

mpn: F2504-15,
The National Scientific F2504-15 is a filter for particulate removal from samples of less than 2mL prior to HPLC analysis, for use with Target syringe filters (sold separately). This filter is constructed of cellulose acetate, with a housing construc...

mpn: F2513-17,
The polypropylene housings with all Target syringe filters are solvent resistant and exhibit low extractables. Ideal for filtering chromatography solvents and samples when combined with low extractable Nylon, Regenerated Cellulose or PTFE membranes. ...

mpn: F2513-7,
The polypropylene housings with all Target syringe filters are solvent resistant and exhibit low extractables. Ideal for filtering chromatography solvents and samples when combined with low extractable Nylon, Regenerated Cellulose or PTFE membranes. ...

mpn: F2600-1,
Syringe Filters 30 mm, 0.45 Pore Size, Nylon - 100 PackIncreased diameters over conventional sizes. 50% more sample throughput. Virgin polypropylene housing. ...

mpn: F2613-1,
Syringe Filters 17 mm, 0.45, Pore Size, Nylon - 100 PackLarger surface area for faster sample throughput. Hold-up volume of only . All filters feature virgin polypropylene housing for both aqueous and solvent based samples. ...

mpn: F2613-2,
Syringe Filters 17 mm, 0.2, Pore Size, Nylon - 100 PackLarger surface area for faster sample throughput. Hold-up volume of only . All filters feature virgin polypropylene housing for both aqueous and solvent based samples. ...

mpn: F2613-3,
Syringe Filters 17 mm, 0.45, Pore Size, PTFE - 100 PackLarger surface area for faster sample throughput. Hold-up volume of only . All filters feature virgin polypropylene housing for both aqueous and solvent based samples. ...



Privacy Policy / Terms of Service
© 2018 - inthenationalinterest.com. All Rights Reserved.